The primary end point was death from cardiac causes, and secondar

The primary end point was death from cardiac causes, and secondary end points were death from any cause and death from arrhythmia during a mean follow-up of 30 +/- 11 years. Early repolarization was stratified according to Selinexor price the degree of J-point elevation (>= 0.1 mV or >0.2 mV) in either inferior or lateral leads.

RESULTS

The early-repolarization pattern of 0.1 mV

or more was present in 630 subjects (5.8%): 384 (3.5%) in inferior leads and 262 (2.4%) in lateral leads, with elevations in both leads in 16 subjects (0.1%). J-point elevation of at least 0.1 mV in inferior leads was associated with an increased risk of death from cardiac causes (adjusted relative risk, 1.28; 95% confidence interval [CI], 1.04 to 1.59; P=0.03); 36 subjects (0.3%) with J-point elevation of more than 0.2 mV in inferior leads had a markedly elevated risk of death from cardiac causes (adjusted relative risk, 2.98; 95% CI, 1.85 to 4.92; P<0.001) and from arrhythmia (adjusted relative risk, 2.92; 95% CI, 1.45 to 5.89; P=0.01). Other electrocardiographic risk markers, such as a prolonged QT interval corrected for heart rate (P=0.03) and left ventricular hypertrophy (P=0.004), were weaker predictors

of the primary end point.

CONCLUSIONS

An early-repolarization pattern in the inferior leads of a standard electrocardiogram is associated with an increased risk of death from cardiac causes in middle-aged subjects.”
“BACKGROUND

In most patients with stable coronary artery disease, Blebbistatin research buy plasma

cardiac troponin T levels are below the limit of detection for the conventional assay. The distribution and determinants of very low circulating troponin T levels, as well as their association with cardiovascular events, in such patients are unknown.

METHODS

We used a new, high-sensitivity assay to determine the concentration of cardiac troponin T in plasma samples from 3679 patients with stable coronary artery disease and preserved left ventricular function. Results of the assay were analyzed in relation to the incidence of cardiovascular events during a median follow-up period of 5.2 years.

RESULTS

With the highly sensitive assay, concentrations of cardiac troponin T were at or above the Z-DEVD-FMK limit of detection (0.001 mu g per liter) in 3593 patients (97.7%) and at or above the 99th percentile for apparently healthy subjects (0.0133 mu g per liter) in 407 patients (11.1%). After adjustment for other independent prognostic indicators, there was a strong and graded increase in the cumulative incidence of cardiovascular death (adjusted hazard ratio per unit increase in the natural logarithm of the troponin T level, 2.09; 95% confidence interval [CI], 1.60 to 2.74; P<0.001) and of heart failure (adjusted hazard ratio, 2.20; 95% CI, 1.66 to 2.90; P<0.001) in this study group.